Safety and continued use of the levonorgestrel intrauterine system as compared with the copper intrauterine device among women living with HIV in South Africa: A randomized controlled trial
Authors:
Catherine S. Todd aff001; Heidi E. Jones aff002; Nontokozo Langwenya aff003; Donald R. Hoover aff004; Pai-Lien Chen aff005; Gregory Petro aff006; Landon Myer aff003
Authors place of work:
Maternal and Child Health and Nutrition Department, Global Health, Population, and Nutrition, Durham, North Carolina, United States of America
aff001; Department of Epidemiology and Biostatistics, City University of New York School of Public Health, New York, New York, United States of America
aff002; Division of Epidemiology and Biostatistics, School of Public Health and Family Medicine, University of Cape Town, Observatory, Cape Town, South Africa
aff003; Department of Statistics and Institute for Health Care Policy and Aging Research, Rutgers University, Piscataway, New Jersey, United States of America
aff004; Global Population and Health Research Department, Global Health, Population, and Nutrition, Durham, North Carolina, United States of America
aff005; Department of Obstetrics and Gynaecology, University of Cape Town, Observatory, Cape Town, South Africa
aff006; New Somerset Hospital, Cape Town, South Africa
aff007; Division of Epidemiology and Biostatistics, Centre for Infectious Diseases Epidemiology and Research, School of Public Health and Family Medicine, University of Cape Town Observatory, Cape Town, South Africa
aff008
Published in the journal:
Safety and continued use of the levonorgestrel intrauterine system as compared with the copper intrauterine device among women living with HIV in South Africa: A randomized controlled trial. PLoS Med 17(5): e32767. doi:10.1371/journal.pmed.1003110
Category:
Research Article
doi:
https://doi.org/10.1371/journal.pmed.1003110
Summary
Background
Women living with HIV (WLHIV) have lower rates of contraceptive use than noninfected peers, yet concerns regarding contraceptive efficacy and interaction with antiretroviral therapy (ART) complicate counseling. Hormonal contraceptives may increase genital tract HIV viral load (gVL) and sexual transmission risk to male partners. We compared gVL, plasma VL (pVL), and intrauterine contraceptive (IUC) continuation between the levonorgestrel intrauterine system (LNG-IUS) and copper intrauterine device (C-IUD) in Cape Town, South Africa.
Methods and findings
In this double-masked, randomized controlled noninferiority trial, eligible WLHIV were ages 18–40, not pregnant or desiring pregnancy within 30 months, screened and treated (as indicated) for reproductive tract infections (RTIs) within 1 month of enrollment, and virologically suppressed using ART or above treatment threshold at enrollment (non-ART). Between October 2013, and December 2016, we randomized consenting women within ART groups, using 1:1 permuted block randomization stratified by ART use, age (18–23, 24–31, 32–40), and recent injectable progestin contraceptive (IPC) exposure, and provided the allocated IUC. At all visits, participants provided specimens for gVL (primary outcome), pVL, RTI, and pregnancy testing. We assessed gVL and pVL across 6 and 24 months controlling for enrollment measures, ART group, age, and RTI using generalized estimating equation and generalized linear models (non-ART group pVL and hemoglobin) in as-treated analyses. We measured IUC discontinuation rates with Kaplan-Meier estimates and Cox proportional hazards models. We enrolled 71 non-ART (36 LNG-IUS, 31 C-IUD; 2 declined and 2 were ineligible) and 134 ART-using (65 LNG-IUS, 67 C-IUD; 1 declined and 1 could not complete IUC insertion) women. Participant median age was 31 years, and 95% had 1 or more prior pregnancies. Proportions of women with detectable gVL were not significantly different comparing LNG-IUS to C-IUD across 6 (adjusted odds ratio [AOR]: 0.78, 95% confidence interval [CI] 0.44–1.38, p = 0.39) and 24 months (AOR: 1.03, 95% CI: 0.68–1.57, p = 0.88). Among ART users, proportions with detectable pVL were not significantly different at 6 (AOR = 0.83, 95% CI 0.37–1.86, p = 0.65) and 24 months (AOR = 0.94, 95% CI 0.49–1.81, p = 0.85), whereas among non-ART women, mean pVL was not significantly different at 6 months (−0.10 log10 copies/mL, 95% CI −0.29 to 0.10, p = 0.50) between LNG-IUS and C-IUD users. IUC continuation was 78% overall; C-IUD users experienced significantly higher expulsion (8% versus 1%, p = 0.02) and elective discontinuation (adjusted hazard ratio: 8.75, 95% CI 3.08–24.8, p < 0.001) rates. Sensitivity analysis adjusted for differential IUC discontinuation found similar gVL results. There were 39 serious adverse events (SAEs); SAEs believed to be directly related to IUC use (n = 7) comprised 3 pelvic inflammatory disease (PID) cases and 4 pregnancies with IUC in place with no discernible trend by IUC arm. Mean hemoglobin change was significantly higher among LNG-IUS users across 6 (0.57 g/dL, 95% CI 0.24–0.90; p < 0.001) and 24 months (0.71 g/dL, 95% CI 0.47–0.95; p < 0.001). Limitations included not achieving non-ART group sample size following change in ART treatment guidelines and truncated 24 months’ outcome data, as 17 women were not yet eligible for their 24-month visit at study closure. Also, a change in VL assay during the study may have caused some discrepancy in VL values because of different limits of detection.
Conclusions
In this study, we found that the LNG-IUS did not increase gVL or pVL and had low levels of contraceptive failure and associated PID compared with the C-IUD among WLHIV. LNG-IUS users were significantly more likely to continue IUC use and had higher hemoglobin levels over time. The LNG-IUS appears to be a safe contraceptive with regard to HIV disease and may be a highly acceptable option for WLHIV.
Trial registration
ClinicalTrials.gov NCT01721798.
Keywords:
pregnancy – HIV – Hemoglobin – Viral load – Hemorrhage – Female contraception – Assisted reproductive technology – Antiretroviral therapy
Introduction
Across sub-Saharan Africa, many women acquire HIV early in their reproductive years. Subsequently, women living with HIV (WLHIV) must balance contraceptive decision-making with the potential impact of HIV infection on pregnancy outcomes and timing, risk of transmission to partners or infants, and appropriate method choice for prevention of pregnancy and sexually transmitted infections [1,2]. WLHIV discontinue hormonal methods more frequently and may have higher rates of unmet contraceptive need than their uninfected peers [3–5].
Intrauterine contraceptives (IUCs) have some of the longest effective durations among long-acting reversible contraceptive (LARC) methods but are not widely used in countries with both high total fertility rates and high HIV prevalence [6,7]. The copper T-380 intrauterine device (C-IUD) is a highly effective contraceptive method that appears to be safe for WLHIV; a Kenyan study among 156 WLHIV not using antiretroviral therapy (ART) found a low incidence of ascending reproductive tract infection (RTI) and no measurable impact on HIV progression [8,9]. However, less is known about levonorgestrel intrauterine system (LNG-IUS) safety for WLHIV.
Systematic reviews and analysis from a large observational cohort suggest that some hormonal contraceptives may be associated with increased HIV progression among or transmission to sexual partners of WLHIV [10,11]. Genital tract viral load (gVL) has been implicated in HIV transmission to male partners and a host of factors are noted to impact gVL, potentially including exogenous progestins [12–14]. LNG-IUS users experience sustained low serum LNG concentrations and relatively higher local LNG tissue concentrations [15,16], but few studies have evaluated genital tract HIV RNA shedding among WLHIV using the LNG-IUS. One small case series evaluated 12 WLHIV, 10 of whom were receiving ART in Finland for 12 months post-LNG-IUS insertion [17], and another followed 25 WLHIV not using ART in Kenya for 6 months [18]. In these studies, women served as their own controls, and the presence or quantity of plasma and genital tract HIV RNA was compared over time, with no significant change noted in either study. Similarly, for the C-IUD, Richardson and colleagues compared samples from 96 WLHIV not using ART immediately prior to and 6 months after C-IUD placement and found no significant change in cervical HIV RNA detection [19]. Although these studies are notable for relatively high IUC continuation rates, most were of short duration, had small sample sizes, and lacked a comparator group, relying on a crossover design. A systematic review including these and other smaller studies concluded that genital tract shedding likely does not increase with IUC use among WLHIV but that supporting evidence quality regarding shedding is fair to poor [20].
Data for whether IUCs are safe for use among WLHIV and, specifically, whether IUCs impact gVL is germane given expanded global ART use and findings of persistent detectable gVL among WLHIV virally suppressed with very low to undetectable plasma viral load (pVL) [21–23]. There are emerging concerns that HIV acquisition and transmission risk may increase in the presence of RTIs, non-Lactobacillus dominant microbiota, and hormonal contraceptives because of local interaction with ART agents [24–26]. Thus, evidence regarding gVL change with exposure to hormonal and nonhormonal IUC use among WLHIV with typical ART use patterns in a context with high background RTI prevalence is timely and may help inform this debate. The purpose of this study was to compare the LNG-IUS with the C-IUD among WLHIV to assess safety concerning HIV transmission and disease progression using the proxy measures of gVL (primary outcome) and pVL (secondary outcome) and by adverse events (AEs) and to assess acceptability as measured by IUC continuation (secondary outcomes). Our hypothesis was that the LNG-IUS was no different from C-IUD regarding change in rates of detectable gVL (noninferiority trial).
Methods
We conducted a double-masked randomized controlled trial with one-to-one allocation comparing the C-IUD (SMB Copper T-380A IUD; SMB Corporation of India, Mumbai, India, or Nova-T Copper T-380 IUD; Bayer Pharmaceuticals, Germany) to the LNG-IUS (Mirena; Bayer Health Care Pharmaceuticals, Montville, NJ) among WLHIV, stratified by enrollment ART status (ART and non-ART users) in Gugulethu, Cape Town, South Africa (clinicaltrials.gov NCT01721798) (please see S1 CONSORT checklist). Women were recruited from surrounding healthcare facilities, community events promoting reproductive health, and radio and newspaper advertisements.
Ethical review
The University of Cape Town Human Research Ethics Committee (#283/2012) and FHI 360 Protection of Human Subjects Committee (#10369/398733) approved the study prior to study activity initiation, and all participants provided written informed consent prior to screening and trial participation.
Eligibility
Eligible women were ages 18–40 years; confirmed as HIV-infected; not pregnant or desiring pregnancy for the next 30 months; at least 6 months postpartum; not planning relocation within 30 months; screened with cervical cytology within the last year (women without a documented cervical cytology report within the last year were offered cytology smear during the pelvic examination at the screening visit in an opt-out fashion to ensure appropriate triage for evidence of neoplasia and eligibility at enrollment visit); without history of ectopic pregnancy, tubal sterilization, or other conditions contraindicating IUC use; and interested in IUC use for contraception. Eligible women using ART had documented pVL < 1,000 copies/mL in the last 6 months, and non-ART women were ART-ineligible at enrollment by CD4 lymphocyte count per local guidelines. As guidelines changed during the trial period, the non-ART arm criteria also changed; when guidelines changed to immediate ART initiation, non-ART women were screened and enrolled and referred for ART at these visits.
Visit procedures
The visit schedule comprised screening, enrollment, and follow-up at 3, 6, 12, 18, and 24 months. All visits were conducted at the study clinic on site at the Gugulethu Community Health Centre in Gugulethu, Cape Town, South Africa. At screening, consenting women were tested for RTIs (Neisseria gonorrhea [NG], Chlamydia trachomatis [CT], Trichomonas vaginalis [TV], Treponema pallidum [TP], and sialidase-positive bacterial vaginosis [BV]) and treated for reactive test results. At enrollment, women had either nonreactive results for all pathogens within 30 days or were 2 to 4 weeks posttreatment for reactive tests; women could be screened up to 3 times. Women were encouraged to continue their current contraceptive method until enrollment; for those reporting injectable progestin contraceptive (IPC) use (depot medroxyprogesterone acetate [DMPA] or norethisterone enanthate), enrollment was scheduled synchronously with the next IPC dose to mitigate potential residual hormonal effect on gVL measures while sustaining contraception [10]. Staff scheduled visits to avoid menstrual bleeding, with visits rescheduled for reported or clinically observed bleeding, and asked participants to avoid vaginal intercourse or douching 48 hours prior to visits.
At enrollment, participants completed an interview-administered baseline questionnaire on sociodemographic characteristics, reproductive and sexual history, menstrual bleeding, and pelvic symptoms; follow-up visit questionnaires also queried IUC acceptability and changes in partnership status and HIV care. At all visits, women inserted menstrual cups (Instead Softcup; Evofem, San Diego, CA, United States of America) for genital tract sample collection, provided urine specimens for pregnancy testing, and provided blood for pVL. At all visits except 3 months, full blood count and CD4 testing (non-ART group) were also conducted. A study nurse certified in IUC insertion provided the LNG-IUS or C-IUD at the end of the enrollment visit based on randomized allocation. Each visit included pelvic examination to collect swabs for RTI testing, bimanual exam, and, at follow-up visits, string visualization to confirm IUC placement. If strings were not visible, immediate onsite ultrasound was used to confirm IUC presence and intrauterine placement. During visits, the study nurse inquired regarding bleeding or other symptoms, which were tracked within an AE register.
Participants were counseled about possible bleeding pattern changes, how to check strings, and notifying the clinic immediately if the IUC was expelled, heavy or abnormal bleeding occurred, or symptoms concerning for RTI or pregnancy occurred. Women were further counseled they could have the IUC removed at any time and a new method provided. Women requesting IUC removal and agreeing to continue with the study were retained through the 24-month visit but excluded from all as-treated (AT) analyses; the only participants terminated from the study were those with diagnosed pregnancy. Women presenting within 72 hours of complete IUC expulsion or with recognized partial expulsion on examination were offered replacement with the allocated IUC if a pregnancy test was negative. Women with clinically diagnosed pelvic inflammatory disease (PID) were offered IUC removal and treated according to national protocols [27]; these women received close follow-up.
Laboratory testing
Plasma and genital tract specimens were tested for HIV RNA at the South African National Health Laboratory Service (NHLS) using the Abbott M2000SP/RT VL assay (Abbott Diagnostics, IL, USA) until June 2015, then subsequently with Roche COBAS TaqMan HIV-1 v2·0 assay (Roche Diagnostics, Mannheim, Germany) with lower limits of detection (LoDs) of 40 and 20 copies/mL, respectively [28]. RTI testing comprised NG and CT nucleic acid amplification testing with NG/CT Xpert (Cepheid Diagnostics, Sunnyvale, CA, USA), TV and BV rapid diagnostic tests (RDTs) for genital tract specimens with OSOM Trichomonas and BV Blue (Sekisui Diagnostics, Lexington, MA, USA), and TP with Alere Determine Syphilis (Alere Diagnostics, San Diego, CA, USA) RDT for whole blood with reflex Rapid Plasma Reagin titer testing of plasma, according to package instructions. Hematological testing comprised CD4 lymphocyte count (non-ART group) using Beckman Coulter XL flow cytometry and complete blood count tests, including hemoglobin, all processed on automated platforms per NHLS procedures.
Outcome measures
The primary trial outcome was change in proportions of WLHIV with detectable gVL from baseline across 6 and 24 months of follow-up. At study initiation in 2013, the original primary outcome was change in pVL, and enrollment into the study was originally restricted to non-ART users. With changes in South African guidelines to ART initiation at diagnosis in 2014 [29], we amended the primary outcome to genital HIV shedding, as a proxy for transmission (originally a secondary outcome), and enrollment to include virally suppressed (pVL<1,000 copies/mL) ART-using WLHIV. Secondary outcomes were changes in pVL; other side effects and safety issues related to IUC use, including hemoglobin, overall and related AEs, and serious AEs (SAEs); and acceptability via IUC continuation.
Sample size rationale and adjustment with outcome change
The original sample size and assumptions are presented in S1 Text. With the change in primary outcome in 2014, the original evaluable sample size of 288 was divided into ART and non-ART groups, and power estimates were calculated for change in proportion of WLHIV with detectable gVL between study arms using a 2-sample exact test with enrollment and 6-month visit measures, using a 2-sided α = 0.05. We further assumed a 15% IUC discontinuation rate and a 5% loss to follow-up rate at 6 months. For ART-using women, we estimated that 54 evaluable women in each arm gave 80% power to exclude a difference of at least 27.7% in proportion of women with detectable gVL between arms at 6 months, assuming 22% of ART-using women had detectable gVL [30]. For non-ART women, we estimated that 62 evaluable women in each arm would provide 80% power to measure a 23.7% difference in detectable gVL between arms at 6 months, informed by shedding rates of 61% of the first 36 non-ART participants [22]. For the pooled sample, we estimated 80% power to detect at least a 19.1% difference in detectable gVL with 116 evaluable women in each arm, assuming a pooled baseline gVL of 42.8%. The pooled gVL value was calculated by using non-ART gVL of 61% * 62/116 + estimated ART-user gVL of 22% * 54/116; this was calculated in 2015 at the time of primary outcome change and ART group addition with available evidence [22].
Randomization and masking
We used 1:1 permuted block randomization with block sizes of 4 to 6 stratified by ART use, age (18–23, 24–31, 32–40), and recent IPC exposure. An external data manager generated the randomization scheme and provided the study site with sequentially numbered, sealed envelopes by stratification arm. The study manager or nurse provided each eligible participant the next sequential envelope in their stratum during the enrollment visit, specifying either “Treatment A” or “Treatment B.” Only study nurses conducting insertions and a site manager were unmasked to specific IUC corresponding to arm; all investigators and outcomes assessors were masked. Participants were unmasked at exit visits.
Statistical analysis
Participant baseline demographic and health history data by study arm were summarized using means (± standard deviations), medians (with interquartile ranges), and proportions. IUC expulsions presenting beyond 72 hours or women declining IUC replacement were censored from VL-associated analysis at that time point for AT analyses. Women with positive pregnancy tests had immediate ultrasound and referral as appropriate with IUC removal for cases with partial expulsion; these women were censored from all analyses following pregnancy diagnosis.
For primary and secondary HIV viral load outcomes, we analyzed differences between arms both by AT and intent-to-treat (ITT) using generalized linear models (GLMs) with generalized estimating equations (GEEs) via combined and stratified analysis by ART group. We preferentially selected AT analyses for the primary (gVL) and 2 secondary outcomes (pVL and AEs); ITT analyses are also presented. We selected AT analysis during study design and analysis planning, as the VL outcomes, pVL and gVL (the latter becoming the primary outcome measure), are both safety measures reflective of potential accelerated disease progression and transmission to partners, respectively. As safety outcomes, we believed it was essential to reflect actual exposure to IUCs with the AT approach rather than the more conservative ITT. To compare the primary outcome, change in proportion of women with detectable gVL from baseline pooled across 6 and 24 months, we used GEE with logistic link and exchangeable working correlation structure to estimate crude and adjusted odds ratios (ORs) with 95% confidence intervals (CIs). All models were adjusted for baseline gVL, as the primary outcome was change in gVL, post-IUC insertion, and adjusted for age and ART group, given stratified randomization. In sensitivity analysis, we further adjusted AT models for prespecified hypothesized confounders of concurrent RTI and baseline pVL. Because of differential IUC discontinuation rates between arms, sensitivity analyses using inverse probability-of-discontinuation weights were applied to primary and secondary HIV-related safety outcomes [31], as were sensitivity analyses testing visit month effect and independent working correlation structure.
For analysis of changes in pVL, 2 approaches were used. For ART users, we used GEE to generate ORs with 95% CIs to evaluate detectable pVL rates between arms from baseline pooled across 6 and 24 months. For non-ART women, we used GLM with identical link to estimate mean change in log10 pVL between arms from baseline pooled across 6 months; we did not analyze across 24 months, as many non-ART women initiated ART during that period. The adjusted models for both ART groups included the previously prespecified confounders and baseline VL measures. For analyses of VL as a continuous measure with log10 values, participants with “undetectable” or lower than LoD results were assigned the value of 20 copies/mL, representing the lowest LoD of the 2 commercial assays used for VL measures and the midpoint between 0 and LoD of the assay with the higher LoD. Previous studies have used either approach (the manufacturer’s LoD to quantify undetectable measures [18,32–34] or the value between 0 and the LoD for undetectable values [35–37]). As VL tests were run through NHLS and assays were changed midway through the study, we believe using the value of 20 copies/mL represents the best assigned value for undetectable VL measures.
For the secondary acceptability outcome of discontinuation, we used Kaplan-Meier models with log-rank tests to estimate and compare cumulative discontinuation probabilities between arms, both overall and stratified by ART group. We also estimated crude and adjusted hazard ratios (aHRs) of discontinuation, adjusting for prespecified covariates of age, ART status, and concurrent RTI, using Cox proportional hazards models. The proportional hazard assumptions of Cox models were examined using Schoenfeld residuals, which do not reject that assumption with p = 0.134. AEs were summarized by those considered related to IUC use and by system organ class, pooled across study arms. Percentages of participants experiencing each AE (1 or more times) were calculated, and we analyzed differences between arms using chi-squared or, for comparisons with 5 or fewer individuals in 1 group, Fisher’s exact tests. We describe SAEs deemed related to IUC use by arm and with rates based on time contributed in an AT model. We compared mean absolute change in hemoglobin (g/dL) between arms across 6 and 24 months in pooled and ART group-stratified analysis using the same approach as for non-ART group pVL analysis. Statistical analyses were performed using SAS 9.4 (SAS Institute, Cary, NC). For further details on analytic approach and rationale, please see S1 Text for the study protocol and S2 Text for the statistical analysis plan.
Results
Participant characteristics and baseline measures
Of 205 women enrolled from October 2013 to December 2016, 199 contributed data for analysis through study closure in July 2018 (Fig 1).
More than 85% of participants continued through the 6-month and end-of-study visits. Because of clinical activity closure in July 2018, 17 women (16 ART users, 1 non-ART user) were not eligible for the 24-month visit; as such, we did not conduct a 24-month visit with VL and RTI measures for these participants. Instead, to ensure informed contraceptive decision-making, we conducted exit visits to unmask these participants and ask whether they wished to retain their IUC. We also did telephone follow-up with these participants at the time of 24-month visit eligibility to assess IUC retention in women who elected to continue their allocated IUC at exit visit.
Most participants had been pregnant at least once and had a mean age of 31.4 years (Table 1). Only one-fifth had completed secondary education, and more than 80% reported having 1 partner over the last 12 months. At screening, RTIs were common, diagnosed among approximately 40% of women, particularly in the non-ART group, with BV, TV, and CT being the most frequent RTIs detected. At enrollment, more than 10% of ART users and 55% of non-ART women had detectable gVL; there were no significant differences in proportion of women with detectable gVL between study arms within each ART group.
Safety regarding genital tract and plasma HIV RNA
Detectable levels of genital tract HIV RNA were consistently present in at least 8% of participants at any time point, irrespective of ART status (Fig 2).
Approximately one-fifth of ART users had detectable pVL at enrollment, and this increased steadily within this group across the cohort period, mirrored by detectable gVL. Larger proportions of women in the non-ART group at enrollment had undetectable or suppressed pVL values starting from 18 months’ follow-up, with related trends in gVL.
There were no significant differences between study arms in proportions of women with detectable gVL in all models and by ART group (Table 2). In sensitivity analyses including censoring adjustment for differential IUC discontinuation, adjustment for visit month effect, and independent working correlation, we found no substantive change in odds of detectable gVL between arms (S1–S3 Tables).
We also detected no significant difference in detectable gVL between baseline compared with combined 3- and 6-month visit measures for each IUC (Table 3).
For the secondary pVL outcome, there was no significant difference in odds of detectable pVL between arms for any analytic approach among ART users (Table 4). For non-ART users, there was no significant difference in mean change in log10 pVL across 6 months; we did not analyze end visit data, as 18.0% (n = 11) of non-ART women reported initiating ART by the exit visit, with 6.3% of initiations occurring by the 12-month visit. These findings were similar in sensitivity analyses identical to those used for gVL (S4–S6 Tables).
Safety regarding reproductive and systemic health measures
At least 1 AE was reported by 98% of participants in each arm. Specific AEs potentially related to IUC use were common, and some differed significantly between study arms, with menorrhagia, dysmenorrhea, and anemia more prevalent among C-IUD users and amenorrhea more common among LNG-IUS users (Table 5). Non-ART women reported pelvic pain, dysmenorrhea, and bloating in higher proportions than ART users. There were 39 SAEs, including 2 deaths unrelated to IUC use (LNG-IUS: smoke inhalation; C-IUD: brief illness disclosed by family), 3 cases of PID (2 LNG-IUS, rate = 1.2/100 person-years [p-y], 95% CI 0.3–4.6), 1 C-IUD (rate = 0.7/100 p-y, 95% CI 0.1–4.9, p = 0.68; overall rate = 0.9/100 p-y, 95% CI 0.3–2.9), and 4 pregnancies with IUC in place (2 ectopic pregnancies in C-IUD users; 1 incomplete abortion with no IUC recovered in a C-IUD user, suggesting unrecognized expulsion; and 1 intrauterine pregnancy in an LNG-IUS user). Pregnancy rates with IUC in place were 1.3/100 p-y overall (95% CI 0.4–3.3), with 2.1/100 p-y (95% CI 0.7–6.5) for C-IUD and 0.6/100 p-y (95% CI 0.1–4.6) for LNG-IUS (p = 0.26). There were no recognized cases of uterine perforation.
For an objective measure of bleeding, we compared hemoglobin change between arms in AT analysis to present relative change concomitant with IUC use. Generally, change in hemoglobin from baseline was significantly higher among LNG-IUS users compared with C-IUD users (Table 6). Changes were markedly higher at the 6-month visit than at the 24-month visit for non-ART women, compared with steady increases in ART users using the LNG-IUS.
IUC expulsion and discontinuation
IUC continuation was 78% (155/199) across all participants during the cohort period; the overall IUC expulsion rate was 2.8/100 p-y, 95% CI 1.5–5.5. Expulsion (5.6/100 p-y, 95% CI 2.8–11.1 for C-IUD versus 0.6/100 p-y, 95% CI 0.10–4.1 for LNG-IUS, p = 0.03) and all-cause discontinuation rates (35% for C-IUD versus 6% for LNG-IUS, p ≤ 0.001; Fig 3) were significantly higher among women using the C-IUD.
Elective discontinuation hazards were significantly higher for C-IUD (aHR = 8.61, 95% CI 3.03–24.4, p < 0.001) users. Overall IUC discontinuation did not differ significantly by ART status (aHR = 1.12, 95% CI 0.11–11.40, p = 0.92), though non-ART women tended to request discontinuation earlier than ART users (S1 Fig).
Discussion
We found no significant difference in proportions of women with detectable gVL between LNG-IUS and C-IUD arms and no change in detectable gVL prior to insertion compared across 3 and 6 months following insertion of either IUC. Similarly, there was no significant difference in proportions of women with detectable pVL (for ART users) or mean change in log10 pVL (for non-ART users) between IUC arms. We also demonstrated that the LNG-IUS had significantly higher continuation during the study (96% for LNG-IUS versus 59% for C-IUD), reflecting greater acceptability of the LNG-IUS than the C-IUD. There were few cases of PID, and the IUC had a high overall continuation rate, which is notable among a population with high background rates of curable RTIs. We achieved our study aim to measure IUC safety with regard to HIV disease and AEs, as well as relative acceptability through continuation rates, although the sample size in the non-ART group was smaller than originally planned.
We selected gVL as a proxy measure for transmission risk given association between gVL and sexual transmission to male partners in discordant couples [12,38]. There are limited data regarding quantity at which gVL substantively increases transmission risk, though 1 publication suggests transmission is unlikely below 400 copies/mL in ART-using populations [39]. Our safety findings for odds of having detectable gVL did not change with exposure to either IUC or between study arms across 6 and 24 months even after adjusting for ART use, RTI, and pVL, and in sensitivity analyses adjusted for disproportionate IUC discontinuation between arms. Chinula and colleagues found reduced proportions of women with detectable gVL following LNG implant use at 6 months for tear flow strip samples (17.7% and 3.2%, representing follicular and luteal phase measurements prior to method initiation at baseline, versus 6.1% at 180 days; adjusted risk ratio [aRR] = 0.40 [95% CI 0.18–0.85], adjusted for baseline pVL and CD4 count), compared with no significant change in women using DMPA (12.1% and 10.7% at baseline versus 10.3% at 180 days, aRR = 1.37 [95% CI 0.81–2.33]) among WLHIV reporting ART use in Malawi [40]. For the same cohort followed up to a maximum of 33 months, Kourtis and colleagues found that risk of detectable gVL did not differ significantly over time after initiation of either method (aRR, 0.97; 95% CI 0.84–1.13, per increase of 6 months of follow-up) or between the DMPA study arm compared with the LNG implant study arm (aRR, 1.92; 95% CI 0.97–3.79) [37]. In this extended cohort period, detectable gVL also did not significantly differ before method initiation compared with follow-up visits (p = 0.47). In a prospective cohort of WLHIV initiating ART that measured detectable gVL, defined as >400 copies/mL from endocervical swab, 30.3% of women reporting ART use had detectable gVL at 1 or more visits; and DMPA (OR 0.96, 95% CI 0.44–2.13) exposure was not associated with detectable gVL [34]. In a Burkina Faso cohort of women with high background rates of RTI, 45% (77/170) of women had detectable gVL at 1 or more visits despite ART use with undetectable pVL [22]. In this cohort, neither reported oral contraceptive (aOR = 1.57, 95% CI 0.75–3.27) nor DMPA use (aOR = 1.32, 95% CI 0.42–4.16) was associated with detectable gVL in analysis adjusted for pVL. Our findings bear distinction from a mucosal immunology standpoint, as the LNG-IUS has markedly higher LNG concentrations in genital tract mucosa, reflecting its largely localized effect, in contrast to the LNG implant and DMPA [41]. When compared with the C-IUD, LNG does not appear to drive shedding via gVL; neither IUC appears to increase gVL through hypothesized inflammatory response from foreign body effect.
There was no significant detectable effect of levonorgestrel from the LNG-IUS on pVL measures between study arms within each ART group, consistent with previous studies [10,11]. Additionally, we found that more than 15% of ART users had pVL > 1,000 copies/mL at any visit after enrollment, consistent with trends attributed to ART nonadherence in Cape Town and the association of detectable gVL with detectable pVL in other studies assessing impact of contraception on genital tract shedding [34,37,40,42]. This finding was associated with increased proportions of women with detectable gVL, irrespective of IUC type and potentially augmented by incident RTIs. Given frequent detectable pVL levels that reflect lack of clinical viral suppression with “real-world ART use” and thus increased probability of transmission among our participants, our findings that neither IUC increased detectable gVL to further increase transmission risk is clinically important. Further, these pVL trends emphasize the need to ensure WLHIV are counseled regarding condom use to prevent transmission to partners when their HIV is not fully suppressed.
We found low numbers of related SAEs, particularly PID, despite relatively high RTI prevalence within our cohort. There were 3 PID cases, occurring in both arms and at levels similar to those reported by studies with comparator groups in some contexts [8,43] but higher than in others [17,44,45]. The cohorts with lower rates were European WLHIV comprising mainly experienced ART users with no reported PID cases [14], a postpartum Zambia cohort recruited prior to Option B+ ART coverage [44], and a Ugandan cohort [45]. For the Zambian study, we believe recruiting postpartum women with no history of PID reduced PID risk because of possible reduced sexual activity in the postpartum period and thus lower exposure to pathogens, evidenced by only 1 case of PID within that cohort of 296 women contributing 642 p-y (0.16/100 p-y) of follow-up [44]. The Ugandan cohort reported 5 cases (2 LNG-IUS and 3 C-IUD) of PID among 672 participants (incidence rate ratio = 0.7, 95% CI 0.06–6.04) with all cases diagnosed and managed by the study site [45]. Our 3 cases include 2 that were diagnosed and managed at other clinical sites, and it is possible that IUC use may have predisposed the external provider to PID diagnosis, as noted in other settings [46,47]. RTIs were measured, detected, and treated at screening (prevalence data); continued to occur through the cohort period; and were largely asymptomatic with few findings on exam [48]. Given the high prevalence of asymptomatic infections, RTI testing using point-of-care tests rather than syndromic management (the standard of care) should be added within IUC insertion guidelines to reduce risk of PID specifically related to IUC use and thus address some provider concerns that likely hamper offering IUCs to WLHIV [20,49]. There were 2 ectopic pregnancies, both occurring with the C-IUD, a propensity noted previously and possibly magnified in this cohort because of high RTI prevalence with tubal scarring [50]. The overall pregnancy rate was higher than expected based on some studies that found pregnancy rates between 0.06 and 1.7/100 p-y [45,50,51] but lower than the 3-year cumulative rate for C-IUD users noted in a large multicenter cohort of 2.8/100 p-y (95% CI 1.3–6.0) [43]. We attribute some of the pregnancies and expulsions to IUC malposition, which may have been clinically unrecognizable until the IUC was visible at the cervical os; Bahamondes and colleagues noted similar rates among C-IUD users, which they attributed to issues related to variability in inserter design [43]. C-IUD users had higher expulsion rates, similar to levels reported in other studies [45,52] but in contrast to that noted by Sanders and colleagues in a US cohort, where expulsion rates were 9% at 12 months and significantly higher among LNG-IUS users [51]. We noted partial expulsions during scheduled study visits, particularly for the C-IUD whose narrow inserter may have resulted in clinicians hesitating to move the inserter all the way to the fundus and then back by 1 cm before advancing the IUD into the endometrial cavity because of perforation concerns. AEs potentially related to IUC use were significantly higher for C-IUD users with the exception of amenorrhea, which was higher for LNG-IUS users, and pelvic pain, which was similar between arms. Amenorrhea was not a strong motivator for discontinuation and may have been under-reported as an AE based on individual participant perception. By contrast, menorrhagia was frequently cited as reason for discontinuation based on AE distribution and stated reasons for C-IUD removal.
WLHIV allocated to the LNG-IUS generally had significant and steady increases in hemoglobin [53]. This increase was more dramatic among non-ART women in the first 6 months than in the interval between 6 and 24 months and may reflect interaction with untreated disease, as many women enrolled in the non-ART group later reported ART use, evidenced by increase in proportions with undetectable pVL by 18 months.
In this trial, the primary and secondary outcomes focused on ensuring IUC safety for WLHIV before and during ART use; however, as IUCs are meant to be LARC methods, acceptability is critical in determining actual use. In this context, the significantly higher LNG-IUS continuation rate observed here is notable. Kakaire and colleagues found similar continuation rates between the C-IUD and LNG-IUS, both exceeding 90%, among WLHIV in Uganda across 12 months [43]. We found much higher LNG-IUS continuation, and among women requesting IUC removal, mean time to discontinuation for both IUCs was less than 1 year, which may reflect differing contextual norms around tolerance of contraceptive side effects or perceived contraceptive availability [43,52].
Our IUC study is among few whose follow-up duration exceeds 12 months, and the high LNG-IUS continuation rate documented here should contribute to expanding access to this LARC method, permitting women broader choice across the reproductive period. Although the LNG-IUS is more expensive than the C-IUD, the significantly higher continuation rate may lead to increased cost-effectiveness relative to other LARC methods that have higher discontinuation rates and thus provide a strong rationale for including the LNG-IUS as a contraceptive option in low- and middle-income countries. This finding is important, as newer versions of the LNG-IUS, bio-identical to the predominant marketed product and approved by regulatory bodies, have been introduced recently with a substantially lower unit cost [54]. These products may potentially make widespread access to LNG-IUS contraception possible, similar to market changes that enabled increased global access to the contraceptive implant [55].
The strengths of this study include the masking of participants and outcome assessors, the randomized design, the inclusion of a nonhormonal method control, the inclusion of both ART and non-ART users, and use of menstrual cup specimens for gVL measurement [30]. However, several limitations are important to note. Our sample size was small for the non-ART group, which was difficult to enroll in light of changing ART guidelines. We also note that among non-ART women screened, many were not eligible because of low CD4 lymphocyte counts constituting ART eligibility by guidelines in effect at study start in 2013. We hypothesize that some non-ART WLHIV preferred not to disclose their status and hence avoided any clinical setting related to HIV care, including the clinic where this study’s clinical activities were conducted. Additionally, a further 17 women were not eligible for their 24-month visit at study closure, resulting in truncated 24-month visit outcome data. We conducted telephone follow-up of these women for the IUC continuation measure when they would have been eligible for the 24-month visit and reached 11 of 17 women, but VL data were missing. Last, the VL assay used by NHLS changed during the study period with VL measures conducted on 2 separate assays for most participants. These assays are both validated but have different LoDs and may have resulted in classification bias with differing precision around VL values.
These data suggest that, compared with the C-IUD, the LNG-IUS does not increase gVL or pVL and has low levels of contraceptive failure and associated PID in WLHIV with high background rates of RTIs. The LNG-IUS had significantly lower overall and elective discontinuation and expulsion rates, suggesting it is a highly acceptable method for WLHIV. These findings may be used to strengthen policies related to IUCs for WLHIV as well as to educate HIV and family planning service providers, and WLHIV themselves, regarding IUCs as a safe contraceptive option.
Supporting information
S1 CONSORT checklist [doc]
CONSORT 2010 checklist of information to include when reporting a randomized trial.
S1 Table [docx]
Odds of detectable genital tract viral load comparing women using the LNG-IUS with those using the C-IUD with linear regression weighted for differential intrauterine contraceptive discontinuation rates, stratified by ART status, among women living with HIV in Cape Town, South Africa.
S2 Table [docx]
Odds of detectable genital tract viral load comparing women using the LNG-IUS with those using the C-IUD with linear regression adjusted by visit month, stratified by ART status, among women living with HIV in Cape Town, South Africa.
S3 Table [docx]
Odds of detectable genital tract viral load comparing women using the LNG-IUS with those using the C-IUD with linear regression using working independent correlation structure, stratified by ART status, among women living with HIV in Cape Town, South Africa.
S4 Table [docx]
Odds of detectable pVL for women using ART or difference in mean change of log10 pVL among women not using ART at enrollment, comparing women using the LNG-IUS with those using the C-IUD, with linear regression weighted for differential intrauterine contraceptive discontinuation rates, among women living with HIV in Cape Town, South Africa.
S5 Table [docx]
Odds of detectable pVL for women using ART or difference in mean change of log10 pVL among women not using ART at enrolment, comparing women using the LNG-IUS with those using the C-IUD, with linear regression adjusted by visit month, among women living with HIV in Cape Town, South Africa.
S6 Table [docx]
Odds of detectable pLV for women using ART or difference in mean change of log10 pVL among women not using ART at enrolment, comparing women using the LNG-IUS with those using the C-IUD, with linear regression using working independent correlation structure, among women living with HIV in Cape Town, South Africa.
S1 Fig [tif]
Kaplan-Meier continuation rate estimates for women using the LNG-IUS compared with women using the C-IUD among women living with HIV in Cape Town, South Africa, by antiretroviral therapy status.
S1 Text [pdf]
Protocol: Comparison of Two IUDs among Cape Town HIV-positive Women: A Randomized Controlled Trial Assessing Safety of Registered Products in South Africa.
S2 Text [pdf]
Comparison of Two IUDs among Cape Town HIV-positive Women: A Randomized Controlled Trial Assessing Safety of Registered Products in South Africa.
Zdroje
1. Harrison A, Colvin CJ, Kuo C, Swartz A, Lurie M. Sustained high HIV incidence in young women in Southern Africa: social, behavioral, and structural factors and emerging intervention approaches. Curr HIV/AIDS Rep. 2015;12: 207–215. doi: 10.1007/s11904-015-0261-0 25855338
2. Pollock LC, Weber S, Kaida A, Matthews LT, Seidman DL. HIV-affected couples and individuals who desire children should be offered options for safer conception. J Int AIDS Soc. 2017;20: 22155. doi: 10.7448/IAS.20.1.22155 28741333
3. Rucinski KB, Powers KA, Schwartz SR, Pence BW, Chi BH, Black V, et al. Longitudinal patterns of unmet need for contraception among women living with HIV on antiretroviral therapy in South Africa. PLoS ONE. 2018;13: e0209114. doi: 10.1371/journal.pone.0209114 30571702
4. Adeniyi OV, Ajayi AI, Moyaki MG, Goon DT, Avramovic G, Lambert J. High rate of unplanned pregnancy in the context of integrated family planning and HIV care services in South Africa. BMC Health Serv Res. 2018;18: 140. doi: 10.1186/s12913-018-2942-z 29482587
5. Todd CS, Anderman TC, Long S, Myer L, Bekker L-G, Petro GA, et al. A systematic review of contraceptive continuation among women living with HIV. Contraception. 2018;98: 8–24. doi: 10.1016/j.contraception.2018.02.002 29432719
6. Cleland J, Ali M, Benova L, Daniele M. The promotion of intrauterine contraception in low- and middle-income countries: a narrative review. Contraception. 2017;95: 519–528. doi: 10.1016/j.contraception.2017.03.009 28365165
7. Morse J, Chipato T, Blanchard K, Nhemachena T, Ramjee G, McCulloch C, et al. Provision of long-acting reversible contraception in HIV-prevalent countries: results from nationally representative surveys in southern Africa. BJOG. 2013;120: 1386–1394. doi: 10.1111/1471-0528.12290 23721413
8. Sinei SK, Morrison CS, Sekadde-Kigondu C, Allen M, Kokonya D. Complications of use of intrauterine devices among HIV-1-infected women. Lancet. 1998;351: 238–41. doi: 10.1016/S0140-6736(97)10319-1
9. World Health Organization. Medical eligibility criteria for contraceptive use. 5th ed. Geneva: World Health Organization; 2015.
10. Heffron R, Donnell D, Rees H, Celum C, Mugo N, Were E, et al. Use of hormonal contraceptives and risk of HIV-1 transmission: a prospective cohort study. Lancet Infect Dis. 2012;12: 19–26. doi: 10.1016/S1473-3099(11)70247-X 21975269
11. Phillips SJ, Polis CB, Curtis KM. The safety of hormonal contraceptives for women living with HIV and their sexual partners. Contraception. 2016;93: 11–16. doi: 10.1016/j.contraception.2015.10.002 26515194
12. Baeten JM, Kahle E, Lingappa JR, Coombs RW, Delany-Moretlwe S, Nakku-Joloba E, et al.; Partners in Prevention HSV/HIV Transmission Study Team. Genital HIV-1 RNA predicts risk of heterosexual HIV-1 transmission. Sci Transl Med. 2011;3: 77ra29. doi: 10.1126/scitranslmed.3001888 21471433
13. Mugo NR, Heffron R, Donnell D, Wald A, Were EO, Rees H, et al.; Partners in Prevention HSV/HIV Transmission Study Team. Increased risk of HIV-1 transmission in pregnancy: a prospective study among African HIV-1-serodiscordant couples. AIDS. 2011;25: 1887–1895. doi: 10.1097/QAD.0b013e32834a9338 21785321
14. Haddad LB, Polis CB, Sheth AN, Brown J, Kourtis AP, King C, et al. Contraceptive methods and risk of HIV acquisition or female-to-male transmission. Curr HIV/AIDS Rep. 2014;11: 447–458. doi: 10.1007/s11904-014-0236-6 25297973
15. Nilsson CG, Haukkamaa M, Vierola H, Luukkainen T. Tissue concentrations of levonorgestrel in women using a levonorgestrel-releasing IUD. Clin Endocrinol (Oxf). 1982;17: 529–536. doi: 10.1111/j.1365-2265.1982.tb01625.x 6819901
16. Andersson K, Odlind V, Rybo G. Levonorgestrel-releasing and copper-releasing (Nova T) IUDs during five years of use: a randomized comparative trial. Contraception. 1994;49: 56–72. doi: 10.1016/0010-7824(94)90109-0 8137626
17. Heikinheimo O, Lehtovirta P, Suni J, Paavonen J. The levonorgestrel-releasing intrauterine system (LNG-IUS) in HIV-infected women—effects on bleeding patterns, ovarian function and genital shedding of HIV. Hum Reprod. 2006;21: 2857–2861. doi: 10.1093/humrep/del264 16880227
18. Coleman JS, Mwachari C, Balkus J, Sanguli L, Muliro A, Agnew K, et al. Effect of the levonorgestrel intrauterine device on genital HIV-1 RNA shedding among HIV-1-infected women not taking antiretroviral therapy in Nairobi, Kenya. J Acquir Immune Defic Syndr. 2013;63: 245–248. doi: 10.1097/QAI.0b013e31828decf8 23446496
19. Richardson BA, Morrison CS, Sekadde-Kigondu C, Sinei SK, Overbaugh J, Panteleeff DD, et al. Effect of intrauterine device use on cervical shedding of HIV-1 DNA. AIDS. 1999;13: 2091–2097. doi: 10.1097/00002030-199910220-00012 10546862
20. Tepper NK, Curtis KM, Nanda K, Jamieson DJ. Safety of intrauterine devices among women with HIV: a systematic review. Contraception. 2016;94: 713–724. doi: 10.1016/j.contraception.2016.06.011 27343750
21. Venkatesh KK, DeLong AK, Kantor R, Chapman S, Ingersoll J, Kurpewski J, et al. Persistent genital tract HIV-1 RNA shedding after change in treatment regimens in antiretroviral-experienced women with detectable plasma viral load. J Womens Health (Larchmt). 2013;22: 330–308. doi: 10.1089/jwh.2012.3849 23531097
22. Low AJ, Konate I, Nagot N, Weiss HA, Kania D, Vickerman P, et al; Yerelon Study Group. Cervicovaginal HIV-1 shedding in women taking antiretroviral therapy in Burkina Faso: a longitudinal study. J Acquir Immune Defic Syndr. 2014;65: 237–245. doi: 10.1097/QAI.0000000000000049 24226060
23. Cu-Uvin S, DeLong AK, Venkatesh KK, Hogan JW, Ingersoll J, Kurpewski J, et al. Genital tract HIV-1 RNA shedding among women with below detectable plasma viral load. AIDS. 2010;24: 2489–2497. doi: 10.1097/QAD.0b013e32833e5043 20736815
24. Nicol MR, Eneh P, Nakalega R, Kaiser T, Kabwigu S, Isingel E, et al. Depot medroxyprogesterone acetate and the vaginal microbiome as modifiers of tenofovir diphosphate and lamivudine triphosphate concentrations in the female genital tract of Ugandan women: Implications for TDF/3TC in pre-exposure prophylaxis. Clin Infect Dis. 2019 May 25;70(8):1717–1724. pii: ciz443. doi: 10.1093/cid/ciz443 31131846
25. Cohen MS, Council OD, Chen JS. Sexually transmitted infections and HIV in the era of antiretroviral treatment and prevention: the biologic basis for epidemiologic synergy. J Int AIDS Soc. 2019;22(Suppl 6): e25355. doi: 10.1002/jia2.25355 31468737
26. McKinnon LR, Achilles SL, Bradshaw CS, Burgener A, Crucitti T, Fredricks DN, et al. The Evolving Facets of Bacterial Vaginosis: Implications for HIV Transmission. AIDS Res Hum Retroviruses. 2019;35: 219–228. doi: 10.1089/AID.2018.0304 30638028
27. Workowski KA, Bolan GA. Sexually transmitted diseases treatment guidelines, 2015. MMWR Recomm Rep. 2015;64: 924. 26042815
28. Stevens WS, Marshall TM. Challenges in implementing HIV load testing in South Africa. J Infect Dis. 2010;201(Suppl 1): S78–84. doi: 10.1086/650383 20225952
29. Provincial Government of the Western Cape-Department of Health, HIV/AIDS/STI/TB (HAST) Directorate. The Western Cape consolidated guidelines for HIV treatment: prevention of mother-to-child transmission of HIV (PMTCT), children, adolescents and adults 2018 (amended version). Cape Town, South Africa: Western Cape Government Health; 2018.
30. Jaumdally SZ, Jones HE, Hoover DR, Gamieldien H, Kriek JM, Langwenya N, et al. Comparison of sampling methods to measure HIV RNA viral load in female genital tract secretions. Am J Reprod Immunol. 2017;77: e12619. doi: 10.1111/aji.12619 28111861
31. Cain LE, Cole SR. Inverse probability-of-censoring weights for the correction of time-varying noncompliance in the effect of randomized highly active antiretroviral therapy on incident AIDS or death. Stat Med. 2009;28: 1725–1738. doi: 10.1002/sim.3585 19347843
32. Masese LN, Graham SM, Gitau R, Peshu N, Jaoko W, Ndinya-Achola JO, et al. A prospective study of vaginal trichomoniasis and HIV-1 shedding in women on antiretroviral therapy. BMC Infect Dis. 2011;11: 307. doi: 10.1186/1471-2334-11-307 22047086
33. Murphy K, Keller MJ, Anastos K, Sinclair S, Devlin JC, Shi Q, et al. Impact of reproductive aging on the vaginal microbiome and soluble immune mediators in women living with and at-risk for HIV infection. PLoS ONE. 2019;14(4): e0216049. doi: 10.1371/journal.pone.0216049 31026271
34. Day S, Graham SM, Masese LN, Richardson BA, Kiarie JN, Jaoko W, et al. A prospective cohort study of the effect of depot medroxyprogesterone acetate on detection of plasma and cervical HIV-1 in women initiating and continuing antiretroviral therapy. J Acquir Immune Defic Syndr. 2014;66: 452–456. doi: 10.1097/QAI.0000000000000187 24798764
35. Greene SA, McGrath CJ, Lehman DA, Marson KG, Trinh TT, Yatich N, et al. Increased Cervical Human Immunodeficiency Virus (HIV) RNA Shedding Among HIV-Infected Women Randomized to Loop Electrosurgical Excision Procedure Compared to Cryotherapy for Cervical Intraepithelial Neoplasia 2/3. Clin Infect Dis. 2018;66: 1778–1784. doi: 10.1093/cid/cix1096 29272368
36. Blish CA, McClelland RS, Richardson BA, Jaoko W, Mandaliya K, Baeten JM, et al. Genital Inflammation Predicts HIV-1 Shedding Independent of Plasma Viral Load and Systemic Inflammation. J Acquir Immune Defic Syndr. 2012;61: 436–440. doi: 10.1097/QAI.0b013e31826c2edd 22878424
37. Kourtis AP, Wiener J, Hurst S, Nelson JAE, Cottrell ML, Corbett A, et al. Brief Report: HIV Shedding in the Female Genital Tract of Women on ART and Progestin Contraception: Extended Follow-up Results of a Randomized Clinical Trial. J Acquir Immune Defic Syndr. 2019;81: 163–165. doi: 10.1097/QAI.0000000000002011 31095006
38. Quinn TC, Wawer MJ, Sewankambo N, Serwadda D, Li C, Wabwire-Mangen F, Meehan MO, et al. Viral load and heterosexual transmission of human immunodeficiency virus type 1. Rakai Project Study Group. N Engl J Med. 2000;342: 921–929. doi: 10.1056/NEJM200003303421303 10738050
39. Attia S, Egger M, Müller M, Zwahlen M, Low N. Sexual transmission of HIV according to viral load and antiretroviral therapy: systematic review and meta-analysis. AIDS. 2009;23: 1397–1404. doi: 10.1097/QAD.0b013e32832b7dca 19381076
40. Chinula L, Nelson JAE, Wiener J, Tang JH, Hurst S, Tegha G, et al. Effect of the depot medroxyprogesterone acetate injectable and levonorgestrel implant on HIV genital shedding: a randomized trial. Contraception. 2018;98: 193–198. doi: 10.1016/j.contraception.2018.05.001 29746813
41. Buckner LR, Drobnis EZ, Augustine MS, Rogers LK, Akers J, Mott PD, et al. Cervical and systemic concentrations of long acting hormonal contraceptive (LARC) progestins depend on delivery method: Implications for the study of HIV transmission. PLoS ONE. 2019; 14:e0214152. doi: 10.1371/journal.pone.0214152 31095572
42. Myer L, Dunning L, Lesosky M, Hsiao NY, Phillips T, Petro G, et al. Frequency of Viremic Episodes in HIV-Infected Women Initiating Antiretroviral Therapy During Pregnancy: A Cohort Study. Clin Infect Dis. 2017;64: 422–427. doi: 10.1093/cid/ciw792 27927852
43. Bahamondes L, Brache V, Meirik O, Ali M, Habib N, Landoulsi S; WHO Study Group on Contraceptive Implants for Women. A 3-year multicentre randomized controlled trial of etonogestrel- and levonorgestrel-releasing contraceptive implants, with non-randomized matched copper-intrauterine device controls. Hum Reprod. 2015;30: 2527–2538. doi: 10.1093/humrep/dev221 26409014
44. Stringer EM, Kaseba C, Levy J, Sinkala M, Goldenberg RL, Chi BH, et al. A randomized trial of the intrauterine contraceptive device vs hormonal contraception in women who are infected with the human immunodeficiency virus. Am J Obstet Gynecol. 2007;197: 144.e1–8. doi: 10.1016/j.ajog.2007.03.031 17689627
45. Kakaire O, Byamugisha JK, Tumwesigye NM, Gemzell-Danielsson K. Intrauterine contraception among women living with human immunodeficiency virus: a randomized controlled trial. Obstet Gynecol 2015;126: 928–934. doi: 10.1097/AOG.0000000000001087 26444127
46. Jatlaoui TC, Simmons KB, Curtis KM. The safety of intrauterine contraception initiation among women with current asymptomatic cervical infections or at increased risk of sexually transmitted infections. Contraception. 2016;94: 701–712. doi: 10.1016/j.contraception.2016.05.013 27263041
47. Grimes DA. Intrauterine device and upper-genital-tract infection. Lancet. 2000;356: 1013–1019. doi: 10.1016/S0140-6736(00)02699-4 11041414
48. Langwenya N, Todd C, Jones H, Hoover DM, Ronan A, Myer L. Reproductive tract infection risk-based screening for IUD insertion in HIV+ women. Poster 1075. Proceedings of the 2018 Conference on Retroviruses and Opportunistic Infections (CROI); 2018 March 5; Boston, Massachusetts, US.
49. Hoke T, Harries J, Crede S, Green M, Constant D, Petruney T, et al. Expanding contraceptive options for PMTCT clients: a mixed methods implementation study in Cape Town, South Africa. Reprod Health. 2014;11: 3. doi: 10.1186/1742-4755-11-3 24410922
50. Heinemann K, Reed S, Moehner S, Minh TD. Comparative contraceptive effectiveness of levonorgestrel-releasing and copper intrauterine devices: the European Active Surveillance Study for Intrauterine Devices. Contraception. 2015;91: 280–283. doi: 10.1016/j.contraception.2015.01.011 25601350
51. Simonatto P, Bahamondes MV, Fernandes A, Silveira C, Bahamondes L. Comparison of two cohorts of women who expulsed either a copper-intrauterine device or a levonorgestrel-releasing intrauterine system. J Obstet Gynaecol Res. 2016;42: 554–559. doi: 10.1111/jog.12939 26817571
52. Lowe RF, Prata N. Hemoglobin and serum ferritin levels in women using copper-releasing or levonorgestrel-releasing intrauterine devices: a systematic review. Contraception 2013;87: 486–496. doi: 10.1016/j.contraception.2012.09.025 23122687
53. Application seeks to extend duration of use up to 5 years for LILETTA. San Francisco, CA: Medicines 360. 22 Feb 2018. [cited 2020 Mar 24]. Available from: http://www.medicines360.org/2018/02/22/fda-acceptance-of-medicines360s-filing-for-supplemental-new-drug-application-for-liletta-levonorgestrel-releasing-intrauterine-system-52-mg/
54. Rowlands S, Searle S. Contraceptive implants: current perspectives. Open Access J Contracept. 2014;5: 73–84. https://doi.org/10.2147/OAJC.S55968
55. Benova L, Cleland J, Daniele MAS, Ali M. Expanding Method Choice in Africa with Long-Acting Methods: IUDs, Implants or Both? Int Perspect Sex Reprod Health. 2017;43:183–191. doi: 10.1363/43e5217 29874164
Článek vyšel v časopise
PLOS Medicine
2020 Číslo 5
- Antibiotika na nachlazení nezabírají! Jak můžeme zpomalit šíření rezistence?
- FDA varuje před selfmonitoringem cukru pomocí chytrých hodinek. Jak je to v Česku?
- Prof. Jan Škrha: Metformin je bezpečný, ale je třeba jej bezpečně užívat a léčbu kontrolovat
- Ibuprofen jako alternativa antibiotik při léčbě infekcí močových cest
- Jak a kdy u celiakie začíná reakce na lepek? Možnou odpověď poodkryla čerstvá kanadská studie
Nejčtenější v tomto čísle
- National and regional prevalence of posttraumatic stress disorder in sub-Saharan Africa: A systematic review and meta-analysis
- Risk of severe maternal morbidity or death in relation to elevated hemoglobin A1c preconception, and in early pregnancy: A population-based cohort study
- Antibody-based therapies for COVID-19: Can Europe move faster?
- The association of innate and adaptive immunity, subclinical atherosclerosis, and cardiovascular disease in the Rotterdam Study: A prospective cohort study